Typical fixture flow rates
| Fixture | Typical flow |
|---|---|
| Shower | 2 to 2.5 US gpm |
| Kitchen faucet | 1.5 to 2 US gpm |
| Washer filling | 3 to 4 US gpm |
| Toilet refilling | 3 US gpm |
Count only the fixtures that really run together at your busiest time. A two-bathroom home often lands between 8 and 12 US gpm.
Supply flow vs treatment flow
Your well pump or municipal service sets the maximum available. Each piece of equipment then adds pressure loss. The whole treatment train has to handle your peak, or pressure drops when it matters. See pressure and pressure loss.
UV systems and flow
A UV system certified to NSF/ANSI 55 is validated up to a maximum flow. Above it, exposure time shortens. See sizing UV treatment.
Frequently asked questions
Is daily water use enough to size a system?
No. It sets a softener's capacity, but peak flow sets the valve size and model.
Will a bigger pump fix low pressure?
Not always. It can exceed the validated flow of a UV system or filter. Pump and treatment flow have to match.
How do I measure my flow rate?
Time how long it takes to fill a marked bucket at the tap closest to the pressure tank, or we measure it with a flow meter during our visit.