Reverse osmosis: continuous drain flow or leaks

A reverse osmosis system normally sends water to drain while it's producing. That flow should stop when the tank is full. If it runs day and night, the tank isn't filling or the automatic shut-off valve no longer closes. A visible leak calls for shutting off the supply right away.

Updated October 12, 2026

Normal or not?

SituationNormal?Possible cause
Drain flow while the tank fillsYesProduction reject water
Constant flow, tank fullNoShut-off or check valve
Constant flow, tank emptyNoTank or inlet pressure
Water under the sinkNoFitting, tubing or housing

If there's a leak

Close the RO feed valve, then the tank valve. Check the quick-connect fittings: tubing that isn't fully inserted or was cut at an angle is the most common cause.

Inlet pressure matters

With low water pressure, the system produces slowly and the shut-off valve closes poorly. A booster pump solves this on some wells.

Frequently asked questions

How much water does RO send to drain?

It depends on the model and the pressure. See RO recovery and reject water.

Does constant drain flow raise my water bill?

Yes, and on a well it runs the pump and loads the septic system. It's worth fixing quickly.

Can I keep using it with a small leak?

No. Shut off the supply: a small leak can get worse suddenly.