A UV lamp loses output long before it burns out, so the bulb is replaced every year even if it still glows. At each change the quartz sleeve is cleaned or replaced and the pre-filter checked, so the light reaches all the water.

Updated October 12, 2026

Yearly UV maintenance, step by step

  1. Turn off power and shut off the water.
  2. Take out the lamp without touching the glass with bare hands.
  3. Clean the quartz sleeve, or replace it if scratched or cloudy.
  4. Replace the O-rings and the pre-filter cartridge.
  5. Restore water, power up and reset the lamp timer.

Why replace a bulb that still glows

UV-C output drops with operating hours while the visible glow stays the same. Manufacturers rate lamp life at about one year of continuous use.

When the sleeve needs cleaning more often

Hard or iron-rich water leaves a film on the quartz. If deposits come back quickly, a softener or iron filter upstream protects the sleeve.

Disinfecting after service

If the system was open for a long time or water flowed untreated, disinfecting the plumbing may be recommended. See sanitizing equipment.

Frequently asked questions

How long does a UV bulb last?

About one year of continuous operation for most residential models. Follow the manufacturer's rated life.

Should I turn the UV off when I'm away?

No, except for a seasonal shutdown. Frequent restarts wear the lamp, and standing water needs treatment when you return.

Do NSF/ANSI 55 certified systems need more maintenance?

The schedule is the same: a new lamp every year and a clean sleeve. The right pre-treatment reduces unplanned shutdowns.